3RF2190-3AA22
SEMI-COND. RELAY 3RF2 WIDTH

From SIEMENS

Semiconductor relay, 1-phase 3RF2 Overall width 22.5 mm, 90 A 24-230 V / 110-230 V AC Ring cable connection
General technical data
Product brand nameSIRIUS
Product designationsolid-state relay
Product functionzero-point switching
Number of poles for main current circuit1
Protection class IPIP00
Product designation _1 of the accessories that can be orderedterminal cover
Manufacturer's article number _1 of the accessories that can be ordered
Product designation _4 of the accessories that can be orderedload monitoring
Manufacturer's article number _4 of the accessories that can be ordered
Ambient temperature
during operation°C-25 ... +60
during storage°C-55 ... +80
Installation altitude at height above sea level maximumm1 000
Vibration resistance acc. to IEC 60068-2-62g
Shock resistance acc. to IEC 60068-2-2715g / 11 ms
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750K
Reference code acc. to DIN EN 61346-2Q
Number of NC contacts for auxiliary contacts0
Number of NO contacts for auxiliary contacts0
Number of CO contacts for auxiliary contacts0
Main circuit
Number of NO contacts for main contacts1
Number of NC contacts for main contacts0
Operating current
rated value maximumA88
at AC-51 rated valueA88
minimummA500
Operating voltage at AC
at 50 Hz rated valueV24 ... 230
at 60 Hz rated valueV24 ... 230
Operating range relative to the operating voltage at AC
at 50 HzV20 ... 253
at 60 HzV20 ... 253
Operating frequency rated valueHz50 ... 60
Relative symmetrical tolerance of the operating frequency%10
Insulation voltage rated valueV600
Rate of voltage rise at the thyristor for main contacts maximum permissibleV/µs1 000
Blocking voltage at the thyristor for main contacts maximum permissibleV800
Reverse current of the thyristormA10
Derating temperature°C40
Power loss [W] total typicalW118
Power loss [V∙A] maximumV·A118
Surge current resistance rated valueA1 150
I2t value maximumA²·s6 600
Short-circuit protection, design of the fuse link
Control circuit/ Control
Control supply voltage frequency
1 rated valueHz50
2 rated valueHz60
Type of voltage of the control supply voltageAC
Control supply voltage 1
at AC
— at 50 Hz Initial rated valueV110
— at 50 Hz Final rated valueV230
— at 60 Hz Initial rated valueV110
— at 60 Hz Final rated valueV230
Control supply voltage
at AC
— initial value for signal <1> detectionV90
— at 50 Hz Full-scale value for signal<0> recognitionV40
— at 60 Hz Full-scale value for signal<0> recognitionV40
Symmetrical line frequency toleranceHz5
Relative symmetrical tolerance of the supply voltage frequency%10
Control current
at minimum control supply voltage
— at ACmA2
at AC rated valuemA15
Installation/ mounting/ dimensions
Mounting typescrew fixing
Mounting type Side-by-side mountingYes
Design of the thread of the screw for securing the equipmentM4
Tightening torque of the screw for securing the equipmentN·m1.5
Widthmm22.5
Heightmm85
Depthmm48
Connections/Terminals
Type of electrical connection for main current circuitring cable connection
Design of the thread of the connection screw for main contactsM5
Tightening torque for main contacts with screw-type terminalsN·m2 ... 2.5
Tightening torque [lbf·in] for main contacts with screw-type terminalslbf·in7 ... 10.3
Type of connectable conductor cross-sections
for main contacts
— for JIS cable lugJIS C 2805 R 2-5, 5,5-5, 8-5, 14-5
for DIN cable lug for main contactsDIN 46234 -5-2,5, -5-6, -5-10, -5-16, -5-25
at AWG conductors
— for auxiliary and control contacts1x (AWG 20 ... 12)
for auxiliary and control contacts
— solid1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
— finely stranded
— with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
— without core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
Connectable conductor cross-section
for auxiliary and control contacts
— solidmm²0.5 ... 2.5
— finely stranded
— with core end processingmm²0.5 ... 2.5
— without core end processingmm²0.5 ... 2.5
AWG number as coded connectable conductor cross section
for auxiliary and control contacts20 ... 12
Type of electrical connection for auxiliary and control current circuitring cable connection
Design of the thread of the connection screw of the auxiliary and control contactsM3
Wire stripping length of the cable
for main contactsmm7
for auxiliary and control contactsmm7
Tightening torque for auxiliary and control contacts with screw-type terminalsN·m0.5 ... 0.6
Tightening torque [lbf·in] for auxiliary and control contacts with screw-type terminalslbf·in4.5 ... 5.3

External links