3SB3400-0J-ZX90 ACCESSORY FOR
From SIEMENS
| Contact block with 1 contact element, 1 NO, screw terminal, For front plate mounting, !!! Phased-out product !!! SIRIUS ACT 3SU1 is the successor The preferred successor type is <<3SU1400-1AA10-1BA0-ZX90>> | ||
| Product designation | contact block | |
| Contact block/ lampholder | ||
| Number of lampholders | 0 | |
| General technical data | ||
| Product function | ||
| positive opening | No | |
| Product component | ||
| diode | No | |
| lamp transformer | No | |
| Light source | No | |
| series resistor | No | |
| Insulation voltage | ||
| rated value | 400 V | |
| Degree of pollution | class 3 | |
| Type of voltage | ||
| of the operating voltage | AC/DC | |
| Surge voltage resistance rated value | 4 kV | |
| Protection class IP | ||
| of the enclosure | IP40 | |
| of the terminal | IP20 | |
| Operating frequency maximum | 1 000 1/h | |
| Mechanical service life (switching cycles) | ||
| typical | 10 000 000 | |
| Electrical endurance (switching cycles) with contactors 3RT1015 to 3RT1026 typical | 10 000 000 | |
| Thermal current | 10 A | |
| Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | S | |
| Reference code acc. to DIN EN 81346-2 | S | |
| Reference code acc. to DIN EN 61346-2 | S | |
| Design of the fuse link for short-circuit protection of the auxiliary switch with type of coordination 1 required | gG / Dz 10 A | |
| Operating voltage | ||
| at AC | ||
| — at 50 Hz rated value | 5 ... 400 V | |
| — at 60 Hz rated value | 5 ... 300 V | |
| at DC | ||
| — rated value | 5 ... 230 V | |
| Operating voltage 1 | ||
| at AC | ||
| — at 50 Hz rated value | 400 V | |
| — at 60 Hz rated value | 300 V | |
| at DC rated value | 24 V | |
| Power Electronics | ||
| Contact reliability | one incorrect switching operation of 100 million switching operations (5 V, 1 mA) | |
| Auxiliary circuit | ||
| Number of NC contacts for auxiliary contacts | 0 | |
| Number of NO contacts for auxiliary contacts | 1 | |
| Number of CO contacts | ||
| for auxiliary contacts | 0 | |
| Operating current at AC-12 | ||
| at 24 V rated value | 10 A | |
| at 48 V rated value | 10 A | |
| at 110 V rated value | 10 A | |
| at 230 V rated value | 10 A | |
| at 400 V rated value | 10 A | |
| Operating current at AC-15 | ||
| at 24 V rated value | 6 A | |
| at 48 V rated value | 6 A | |
| at 110 V rated value | 6 A | |
| at 230 V rated value | 6 A | |
| at 400 V rated value | 3 A | |
| Operating current at DC-12 | ||
| at 24 V rated value | 10 A | |
| at 48 V rated value | 5 A | |
| at 110 V rated value | 2.5 A | |
| at 230 V rated value | 1 A | |
| Operating current at DC-13 | ||
| at 24 V rated value | 3 A | |
| at 48 V rated value | 1.5 A | |
| at 110 V rated value | 0.7 A | |
| at 230 V rated value | 0.3 A | |
| Connections/ Terminals | ||
| Type of electrical connection | screw-type terminals | |
| Type of connectable conductor cross-sections | ||
| for auxiliary contacts | ||
| — solid | 2x (1.0 ... 1.5 mm²) | |
| — solid with core end processing | 2x (0.5 ... 0.75 mm²) | |
| — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) | |
| at AWG conductors for auxiliary contacts | 2x (18 ... 14) | |
| Tightening torque | ||
| for auxiliary contacts with screw-type terminals | 0.8 N·m | |
| Ambient conditions | ||
| Ambient temperature | ||
| during operation | -25 ... +70 °C | |
| during storage | -25 ... +80 °C | |
| Installation/ mounting/ dimensions | ||
| Mounting type | front mounting | |
| Height | 36.5 mm | |
| Width | 10 mm | |
| Depth | 20 mm | |
| Certificates/ approvals | ||