| SIMATIC WINAC SLOT 412 V3.3, SINGLE LICENSE F. 1 INSTALL., INCL R-SW, SW AND DOCU. ON CD, CLASS A, 3 LANGUAGES (G,E,F), EXECUTABLE U. WIN 2000/XP PRO, REFERENCE-HW: SIMATIC PC |
| General information |
| HW functional status | 1 |
| Firmware version | V3.1 |
| Input current |
| Current consumption, max. | 1.5 A; from PCI bus without PS Extension Board; 0.3 A with PS Extension Board; current consumption 12 V/24 V via PS Extension Board 1.2 A |
| Power |
| Active power input, typ. | 12 W |
| Memory |
| Work memory |
| integrated | 256 kbyte; 128 Kbytes code + 128 Kbytes data |
| Load memory |
| expandable FEPROM | Yes; Memory Card (FLASH) up to 64 MB |
| expandable FEPROM, max. | 64 Mbyte |
| integrated RAM, max. | 256 kbyte |
| expandable RAM | Yes; Memory Card (FLASH) up to 64 MB |
| expandable RAM, max. | 16 Mbyte |
| Battery |
| Backup battery |
| Backup current, typ. | 130 µA |
| Backup current, max. | 500 µA; Backup battery voltage: 3.6 V Lithium |
| CPU processing times |
| for bit operations, typ. | 0.2 µs |
| for fixed point arithmetic, typ. | 0.2 µs |
| for floating point arithmetic, typ. | 0.6 µs |
| CPU-blocks |
| DB |
| Number, max. | 512 |
| Size, max. | 64 kbyte |
| FB |
| Number, max. | 256 |
| Size, max. | 64 kbyte |
| FC |
| Number, max. | 256 |
| Size, max. | 64 kbyte |
| OB |
| Size, max. | 64 kbyte |
| Number of time alarm OBs | 2 |
| Number of delay alarm OBs | 2 |
| Number of cyclic interrupt OBs | 2 |
| Number of process alarm OBs | 2 |
| Nesting depth |
| per priority class | 24 |
| additional within an error OB | 2 |
| Counters, timers and their retentivity |
| S7 counter |
| Number | 256 |
| Retentivity |
| — adjustable | Yes |
| — lower limit | 0 |
| — upper limit | 255 |
| — preset | Z 0 to Z 7 |
| Counting range |
| — adjustable | Yes |
| — lower limit | 1 |
| — upper limit | 999 |
| IEC counter |
| present | Yes |
| Type | SFB |
| S7 times |
| Number | 256 |
| Retentivity |
| — lower limit | 0 |
| — upper limit | 255 |
| — preset | No retentivity |
| Time range |
| — lower limit | 10 ms |
| — upper limit | 9 990 s |
| IEC timer |
| present | Yes |
| Type | SFB |
| Data areas and their retentivity |
| Retentivity without UPS and PS Extension Board | none |
| Retentivity with UPS | none |
| Retentivity with PS extension board and battery | all data |
| Flag |
| Number, max. | 4 kbyte |
| of which retentive | From MB 0 to MB 4 095 |
| Retentivity preset | MB 0 to MB 15 |
| Number of clock memories | 8 |
| Address area |
| I/O address area |
| Inputs | 4 kbyte |
| Outputs | 4 kbyte |
| Process image |
| Inputs, adjustable | 4 kbyte |
| Outputs, adjustable | 4 kbyte |
| Inputs, default | 128 byte |
| Outputs, default | 128 byte |
| Subprocess images |
| Number of subprocess images, max. | 8 |
| Digital channels |
| Inputs | 32 768 |
| Outputs | 32 768 |
| Analog channels |
| Inputs | 2 048 |
| Outputs | 2 048 |
| Hardware configuration |
| Number of DP masters |
| integrated | 2 |
| Number of operable FMs and CPs (recommended) |
| FM | FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2 |
| CP, LAN | Over PC CP |
| Slots |
| Number of single-width slots, max. | 1; 2 with PC extension board; PCI format 3/4 |
| Time of day |
| Clock |
| Hardware clock (real-time) | Yes |
| retentive and synchronizable | Yes |
| Clock synchronization |
| supported | Yes; to PC-CP: Slave |
| to MPI, master | Yes |
| to MPI, slave | Yes |
| 1. Interface |
| Physics | RS 485 / PROFIBUS |
| Isolated | Yes |
| Protocols |
| MPI | Yes |
| PROFIBUS DP master | Yes |
| PROFIBUS DP slave | Yes |
| MPI |
| Number of connections | 16 |
| Transmission rate, max. | 12 Mbit/s |
| Services |
| — PG/OP communication | Yes |
| — Routing | Yes |
| — Global data communication | Yes |
| — S7 basic communication | Yes |
| — S7 communication | Yes |
| PROFIBUS DP master |
| Number of connections, max. | 16 |
| Transmission rate, max. | 12 Mbit/s |
| Number of DP slaves, max. | 32 |
| Services |
| — PG/OP communication | Yes |
| — Global data communication | No |
| — S7 basic communication | Yes |
| — S7 communication | Yes |
| — Equidistance | Yes |
| — SYNC/FREEZE | Yes |
| — Activation/deactivation of DP slaves | Yes |
| — Direct data exchange (slave-to-slave communication) | Yes |
| — DPV0 | Yes |
| — DPV1 | Yes |
| Address area |
| — Inputs, max. | 2 kbyte |
| — Outputs, max. | 2 kbyte |
| User data per DP slave |
| — User data per DP slave, max. | 244 byte; 244 byte / 244 byte |
| PROFIBUS DP slave |
| Services |
| — Routing | Yes |
| 2. Interface |
| Physics | RS 485 / PROFIBUS |
| Isolated | Yes |
| Protocols |
| MPI | No |
| PROFIBUS DP master | Yes |
| PROFIBUS DP slave | Yes |
| PROFIBUS DP master |
| Number of connections, max. | 16 |
| Transmission rate, max. | 12 Mbit/s |
| Number of DP slaves, max. | 64 |
| Services |
| — PG/OP communication | Yes |
| — Routing | Yes |
| — Global data communication | No |
| — S7 basic communication | Yes |
| — S7 communication | Yes |
| — Equidistance | Yes |
| — SYNC/FREEZE | Yes |
| — Activation/deactivation of DP slaves | Yes |
| — Direct data exchange (slave-to-slave communication) | Yes |
| — DPV0 | Yes |
| — DPV1 | Yes |
| Address area |
| — Inputs, max. | 4 kbyte |
| — Outputs, max. | 4 kbyte |
| User data per DP slave |
| — User data per DP slave, max. | 244 byte; 244 byte / 244 byte |
| PROFIBUS DP slave |
| Services |
| — PG/OP communication | Yes |
| — Routing | Yes |
| Isochronous mode |
| Isochronous operation (application synchronized up to terminal) | Yes |
| Equidistance | Yes |
| Number of DP masters with isochronous mode | 2 |
| User data per isochronous slave, max. | 128 byte |
| shortest clock pulse | 2.5 ms; 2.5 ms without process image partition, 5 ms with process image partition |
| Communication functions |
| PG/OP communication | Yes |
| Global data communication |
| supported | Yes |
| S7 basic communication |
| supported | Yes |
| S7 communication |
| as server | Yes |
| as client | Yes |
| Number of connections |
| overall | 16 |
| usable for PG communication | |
| — reserved for PG communication | 1 |
| usable for OP communication | |
| — reserved for OP communication | 1 |
| S7 message functions |
| Number of login stations for message functions, max. | 8 |
| SCAN procedure | Yes |
| Process diagnostic messages | Yes; Alarm_S |
| Alarm 8-blocks | Yes |
| Process control messages | Yes |
| Test commissioning functions |
| Status block | Yes |
| Single step | Yes |
| Status/control |
| Status/control variable | Yes |
| Forcing |
| Forcing | Yes |
| Diagnostic buffer |
| present | Yes |
| Number of entries, max. | |
| — preset | 120 |
| Hardware requirement |
| Hardware required | Accessories: color monitor, keyboard, mouse or pointer for Windows |
| Processor |
| Processor | Intel Pentium 300 MHz |
| Memory |
| Main memory, min. | 128 Mbyte |
| Required memory on hard disk | 60 Mbyte |
| Operating systems |
| pre-installed operating system |
| Windows 2000 | Yes; Professional, SP3 or higher |
| Windows XP | Yes; Professional, SP1 or higher |
| Configuration |
| Software interface | C/C++ with WinAC Slot T-Kit |
| Configuration software |
| STEP 7 | Yes; V5.2 or higher |
| Programming |
| Nesting levels | 8 |
| Programming language |
| — LAD | Yes |
| — FBD | Yes |
| — STL | Yes |
| — SCL | Yes |
| — CFC | Yes |
| — GRAPH | Yes |
| — HiGraph® | Yes |
| Software libraries |
| — Easy Motion Control | Yes |
| Know-how protection |
| User program protection/password protection | Yes |
| Open Development interfaces |
| SMX (Shared Memory Extension) | |
| — Inputs | 4 kbyte |
| — Outputs | 4 kbyte |
| Dimensions |
| Width | 98 mm |
| Height | 288 mm |
| Weights |
| Weight, approx. | 250 g; 450 g with PC extension board |
| last modified: | 03/13/2019 |