in any other application Where failure of the product could result in Personal injury. Failure to comply with these instructions could Result in death or serious injury. (c) 2009 Honeywell International Inc. 3 www.honeywell.com Honeywell Data Sheet GMS10, KGZ12 and KGZ50 Oxygen Sensors - Probe Style FEATURES * Oxygen pressure range 2 mbar - 3bar * Zirconium dioxide (ZrO2) sensing elements * Non-consumption technology * Integral heating element * No need for temperature stabilisation * No reference gas required * High accuracy * Linear output signal * Operates with external interface boards * 80mm, 220mm and 400mm probes available GMS10RVS ELECTRICAL CONNECTION SPECIFICATIONS Heater Supply* Porous Lid Cap (17.8mm) Stand by Full Porous Cap (15.0mm) Stand by Molex Connector 4.00VDC 0.1VDC (1.7A) 1.65VDC (0.7A) 4.35VDC 0.1VDC (1.85A) 2VDC (0.85A) Pump resistance @ 700C** 1: Pump (Red) 2: Common (Black) 3: Heater (Yellow) 4: Sense (Blue) 5: Heater (Yellow) < 6k Permissible gas temperature Standard Tem
KGZ12 and KGZ50 Oxygen Sensors - Probe Style FEATURES * Oxygen pressure range 2 mbar - 3bar * Zirconium dioxide (ZrO2) sensing elements * Non-consumption technology * Integral heating element * No need for temperature stabilisation * No reference gas required * High accuracy * Linear output signal * Operates with external interface boards * 80mm, 220mm and 400mm probes available GMS10RVS ELECTRICAL CONNECTION SPECIFICATIONS Heater Supply* Porous Lid Cap (17.8mm) Stand by Full Porous Cap (15.0mm) Stand by Molex Connector 4.00VDC 0.1VDC (1.7A) 1.65VDC (0.7A) 4.35VDC 0.1VDC (1.85A) 2VDC (0.85A) Pump resistance @ 700C** 1: Pump (Red) 2: Common (Black) 3: Heater (Yellow) 4: Sense (Blue) 5: Heater (Yellow) < 6k Permissible gas temperature Standard Temp. -100 to 250C Gas flow rate 0 to10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30 g Leadwires Pump (Red) Common (Black) Heater (Yellow) Sense (Blue) Heater (Yellow) * It is important to measure the heater voltage as clo